產(chan)品展(zhan)示
首頁-產品展(zhan)示-空氣(qi)凈化(hua)器(qi)試(shi)驗艙(cang)CADR > 深(shen)圳(zhen)德(de)邁(mai)盛(sheng)觸摸(mo)屏空(kong)氣(qi)凈化(hua)器(qi)測試(shi)艙(cang)CADR空(kong)氣(qi)凈化(hua)器(qi)試(shi)驗艙(cang)CADR



深(shen)圳(zhen)德(de)邁(mai)盛(sheng)觸摸(mo)屏空(kong)氣(qi)凈化(hua)器(qi)測試(shi)艙(cang)CADR空(kong)氣(qi)凈化(hua)器(qi)試(shi)驗艙(cang)CADR
產(chan)品型(xing)號(hao)
CADR更(geng)新(xin)時(shi)間
2025-11-11廠商性質
生產廠家瀏(liu)覽(lan)次數
2194產品中(zhong)心(xin)
PRODUCT CATEGORY相關產品
RELATED PRODUCTS
3立方(fang)空氣(qi)凈化(hua)器(qi)測試(shi)艙(cang)
型(xing)號(hao):
空氣(qi)凈化(hua)器(qi)臭(chou)氧濃度測試(shi)系統(tong)
型(xing)號(hao):
空氣(qi)凈化(hua)器(qi)臭(chou)氧濃度測試(shi)系統(tong)DMS-HH
型(xing)號(hao):DMS-HH
詳細介(jie)紹(shao)
深(shen)圳(zhen)德(de)邁(mai)盛(sheng)觸摸(mo)屏空(kong)氣(qi)凈化(hua)器(qi)測試(shi)艙(cang)CADR
1、深(shen)圳(zhen)德(de)邁(mai)盛(sheng)觸摸(mo)屏空(kong)氣(qi)凈化(hua)器(qi)測試(shi)艙(cang)CADR設(she)備介(jie)紹(shao)
空(kong)氣(qi)凈化(hua)器(qi)試(shi)驗艙(cang)CADR統(tong)包含(han)實(shi)驗室(shi)、空氣(qi)循環裝(zhuang)置、排(pai)氣(qi)系統(tong)、加(jia)樣(yang)采(cai)樣(yang)裝(zhuang)置、設(she)備電器控(kong)制系統(tong)組成(cheng)。
2、試(shi)驗方法
本試(shi)驗主要分為:自(zi)然(ran)衰(shuai)減試(shi)驗和(he)總(zong)衰減試(shi)驗
自(zi)然(ran)衰(shuai)減試(shi)驗如下:
1)將(jiang)待檢測的空(kong)氣(qi)凈化(hua)器(qi)放(fang)置(zhi)於(yu)實(shi)驗室(shi)中(zhong)間(jian)的(de)試(shi)驗臺架上(立式空氣(qi)凈化(hua)器(qi)除(chu)外(wai)),將(jiang)空氣(qi)凈化(hua)器(qi)調(tiao)節(jie)至(zhi)工作狀態,檢查運(yun)行是(shi)否正(zheng)常(chang)後,關閉空(kong)氣(qi)凈化(hua)器(qi);
2)空(kong)氣(qi)凈化(hua)器(qi)試(shi)驗艙(cang)CADR將(jiang)采樣(yang)點(dian)位(wei)置(zhi)布(bu)置(zhi)好(hao),避(bi)開進(jin)出(chu)風(feng)口,離(li)墻(qiang)壁(bi)距離(li)為0.5m,相對(dui)實(shi)驗室(shi)地面高(gao)度為0.5~1.5m,同壹采樣點(dian)可安(an)裝(zhuang)壹個(ge)或多個(ge)采樣(yang)頭(tou),並(bing)與外部(bu)采(cai)樣管連接;
3)將(jiang)排(pai)氣(qi)管道風(feng)閥關閉,開(kai)啟(qi)內循環管(guan)道風(feng)閥,啟(qi)動輔(fu)助(zhu)風(feng)機,使(shi)用(yong)高(gao)效(xiao)過濾器凈化(hua)實(shi)驗室(shi)內空氣(qi),讓(rang)顆粒(li)直徑(jing)為0.3μm以上的粒(li)子背景(jing)濃度小於(yu)檢測初始濃度的千(qian)分之(zhi)壹,同時檢(jian)測實(shi)驗室(shi)內的空(kong)氣(qi)溫度和(he)濕度;
4)等(deng)顆粒(li)物背景濃度降低(di)到(dao)合適(shi)水平,即記錄(lu)當前顆粒(li)物背景濃度,關閉循(xun)環風(feng)機和(he)高(gao)效(xiao)過濾器,啟動家(jia)用吊扇(shan),並(bing)使(shi)用加(jia)樣(yang)裝(zhuang)置,將(jiang)煙霧汙(wu)染(ran)物置於(yu)實(shi)驗室(shi)內,並(bing)且讓(rang)該汙(wu)染(ran)物能夠進(jin)入吊扇(shan)攪拌(ban)產生的空氣(qi)渦流(liu)中(zhong)去(qu),攪拌(ban)10min,等(deng)汙(wu)染(ran)物混合均勻(yun)後關閉家(jia)用(yong)吊扇;
5)吊(diao)扇停(ting)止後,使(shi)用(yong)激(ji)光塵(chen)埃(ai)粒(li)子計數(shu)器(qi)測定(ding)汙(wu)染(ran)物的濃度,壹般(ban)試(shi)驗開始時0.3μm以上的顆粒(li)物的粒(li)子濃度為2000000個(ge)/L
左右,該測試(shi)點(dian)的(de)數(shu)值(zhi)作為實(shi)驗室(shi)內的初始濃度;
6)待初始濃度測定(ding)好(hao)後,開(kai)始檢測試(shi)驗,檢測試(shi)驗過程(cheng)中(zhong)汙(wu)染(ran)物濃度為2min采集(ji)壹起(qi),聯(lian)系測定(ding)20min,要(yao)求至少有(you)9個(ge)數據(ju)點(dian)的(de)濃度大於(yu)儀器(qi)測定(ding)下(xia)限的(de)2倍;
7)記錄(lu)試(shi)驗時的實(shi)驗室(shi)溫濕度;
8)根據測定(ding)的(de)數據即(ji)可計算(suan)出(chu)自(zi)然(ran)衰(shuai)減常(chang)數Kn;
總(zong)衰減試(shi)驗:
1)空氣(qi)凈化(hua)器(qi)試(shi)驗艙(cang)CADR按照上面(1-4)規(gui)定(ding)進(jin)行試(shi)驗;
2)家用吊(diao)扇停(ting)止後,使(shi)用(yong)激(ji)光塵(chen)埃(ai)粒(li)子計數(shu)器(qi)測定(ding)汙(wu)染(ran)物濃度,壹般(ban)試(shi)驗開始時0.3μm以上的顆粒(li)物的粒(li)子濃度為2000000個(ge)/L
左右,該測試(shi)點(dian)的(de)數(shu)值(zhi)作為實(shi)驗室(shi)內的初始濃度;
3)待初始濃度測定(ding)好(hao)後,開(kai)啟(qi)待見(jian)的空(kong)氣(qi)凈化(hua)器(qi),開(kai)始檢測試(shi)驗,檢測過程(cheng)中(zhong)汙(wu)染(ran)物的濃度沒2min測定(ding)壹次,連續測定(ding)20min,要(yao)求至少有(you)9個(ge)數據(ju)點(dian)的(de)濃度大於(yu)儀器(qi)測定(ding)下(xia)限的(de)2倍;
4)關閉空(kong)氣(qi)凈化(hua)器(qi),記錄(lu)試(shi)驗時的實(shi)驗室(shi)溫濕度;
5)根據測定(ding)的(de)數據即(ji)可計算(suan)出(chu)總(zong)衰減常(chang)數Ke。
產品咨詢(xun)

請(qing)填(tian)寫左側(ce)的表格(ge),收到(dao)您(nin)的留(liu)言,我們(men)會(hui)盡快(kuai)與您取(qu)得(de)聯系。